Installation and Operating Instructions
SDC 306 1316BED036-11B-E Date 06/09
- 54 -
13 T
ECHNICAL DATA
SDC
306
Housing
Material 100% recyclable ABS casing for wall-mounted installation
Dimensi
ons (H x W x D) in mm,
weight
175 x 134 x 56; approx. 360 g
Protection class IP20 in accordance with VDE 0470
Electrical values
Operating voltage AC 230 Volt, 50 Hz, -10...+15%
Internal device fuse Micro-fuse 5 x 20mm 2 A/surge-proof
Radio interference level N in accordance with VDE 0875
Maximum cable cross-section
230 V connections
2.5 mm² fine-strand/single-strand
Temperature sensor /
temperature range
PTF6 - 2C - 200°C
PT1000, 1.000 k at 0°C
Testing voltage 4 kV 1 min in accordance with VDE 0631
Switching output
Output depending on switching
output
Total output for all outputs
230 V /
1 A / approx. 230 VA for cos ϕ = 0.7-1.0
2A/ approx. 460 VA
Fuse protection Micro-fuse 5 x 20 mm, 2 A/T (2 amp, fine-wire)
Other
Recommended flow meter PVM 1.5/90 1500l/h, Tmax >=90°C, 10l/impulse
Operating temperature 0 ... + 50°C
Storage temperature -10 ... + 6C
14 R
ESISTANCE TABLE
PT1000
The correct function of the temperature sensor can be checked against the following
temperature resistance table, using a resistance measurement device:
Temperature
in °C
Resistance (Ohms) Temperature
in °C
Resistance (Ohms)
-30 882 60 1232
-20 921 70 1271
-10 960 80 1309
0 1000 90 1347
10 1039 100 1385
20 1077 120 1461
30 1116 140 1535
40 1155 200 1758
50 1194