Installation and Operating Instructions
SDC 306 1316BED036-11B-E Date 06/09
- 47 -
11.16 Basic system diagram 16:
1 collector array, 1 storage cylinder, circulation, anti-Legionnaire’s disease
System 16 has one collector surface, one
storage cylinder, one timer-controlled or
impulse-controlled circulation pump and one
Anti-Legionnaire’s disease function. The
control unit regulates the solar function
(temperature difference regulation), the anti-
Legionnaire’s disease function (thermostat,
timeframe fixed, preset period) and the
impulse-controlled circulation (impulse) or
thermal circulation (thermostat, 2
timeframes). Heat metering is also possible,
e.g. using an impeller flow meter.
For the anti-Legionnaire’s disease function
E2 is used as reference sensor.
Info Program Manual operation Basic setting
I I I I
Current collector temperature (E1) Timeframe 1, circ. start Pump A1 off/on Code entry
Minimum collector temperature (E1) Timeframe 1, circ. stop A2 off/on Reset/factory setting
Maximum collector temperature (E1) Timeframe 2, circ. start A3 off/on Select basic configuration
Current storage temp. at bottom (E2) Timeframe 2, circ. stop A4 off/on Max. collector temperature
Minimum storage temp. - bottom (E2) Max. temp. of storage Mode yield metering
Maximum storage cylinder
temperature at bottom (E2)
Solar circuit Td start
Volume flow
∗
Current circulation temp. (E4)
∗∗∗∗
Solar circuit Td stop
DFG/WMM
∗∗
Minimum circulation temp. (E4)
∗∗∗∗
Thermal switch-on
temperature
∗∗∗∗
Glycol type
∗
Maximum circulation temp. (E4)
∗∗∗∗
Set time
Glycol percentage
∗
Flow rate
∗
Period for anti-Legionnaire’s
function
Daily yield
∗
Tolerance for solar yield
Total yield
∗
Circulation mode
(thermal/impulse)
Switch-on duration for
circulation
∗∗∗
Re-activation lock
∗∗∗
Code change
∗ Displayed only if yield metering is active.
∗∗ Displayed only if yield metering mode is equivalent to 2.
∗∗∗ Displayed only if impulse-controlled circulation is active.
∗∗∗∗ Displayed only if thermal circulation is active.
Comentarios a estos manuales