Installation and Operating Instructions
SDC 306 1316BED036-11B-E Date 06/09
- 43 -
11.12 Basic system diagram 12:
1 collector array, 1 storage cylinder, swimming pool, auxiliary heating
System 12 has one collector surface, one
storage cylinder, one swimming pool and
one auxiliary heating. The control unit
controls the solar function (temperature
difference regulation for storage cylinder
and swimming pool, priority logic), and the
auxiliary heating function (temperature
difference regulation, timeframe). Heat
metering is also possible, e.g. using an
impeller flow meter.
Information Program Manual operation Basic setting
I I I I
Current collector temperature (E1) Timeframe R2 start Pump A1 off/on Code entry
Minimum collector temperature (E1) Timeframe R2 stop A2 off/on Reset/factory setting
Maximum collector temperature (E1) Maximum temperature of
storage cylinder 1
A3 off/on Select basic
configuration
Current temperature of storage
cylinder 1 at bottom (E2)
Solar circuit storage cylinder
1 Td Start
A4 off/on Maximum collector
temperature
Minimum temperature of storage
cylinder 1 at bottom (E2)
Solar circuit storage cylinder
1 Td Stop
Priority storage cylinder
Maximum temperature of storage
cylinder 1 at bottom (E2)
Maximum temperature of
swimming pool
Mode yield metering
Current temperature of storage
cylinder 1 at top (E3)
Solar circuit pool Td start
Volume flow
Minimum temperature of storage
cylinder 1 at top (E3)
Solar circuit pool Td stop
DFG/WMM
∗∗
Maximum temperature of storage
cylinder 1 at top (E3)
Start temperature, auxiliary
heating
Glycol type
Current swimming pool temp. (E4) Set time
Glycol percentage
Minimum swimming pool temp. (E4) Tolerance for solar yield
Maximum swimming pool temp. (E4)
Code change
Flow rate
Daily yield 1/2
Total yield 1/2
Displayed only if yield metering mode is equivalent to 1 or 2.
∗∗ Displayed only if yield metering mode is equivalent to 2.