Installation and Operating Instructions
SDC 306 1316BED036-11B-E Date 06/09
- 30 -
10.2 System monitoring
If an error occurs, the
!
symbol will always flash.
10.2.1 Sensor monitoring
The sensors required for the control
functions and their connection cables are
monitored for breakage and short circuit. If
a defective sensor is recognised by the
software, the
!
symbol is displayed.
The source of the error can be found by
scrolling.
Important:
The use of incorrect temperature
sensors can therefore also lead to one of
the error messages.
10.2.2 Flow monitoring
Display Meaning
!
+
No circulation in solar circuit
In the case of the controller SDC 306, the temperature difference between the collector and the
storage cylinder is checked. If this exceeds the amount of (60K + Td start), this is interpreted
as an error because such large differences should not arise given normal system dimensions
and assuming that the pump is switched on.
In the case of the SDC 306 control unit, the flow quantity is checked when the pump is
switched on. If, for a period of approx. 30 minutes, no flow is detected, this is interpreted as an
error.
The error message is automatically reset once the fault has been removed.
10.2.3 System protection function
The system protection function switches the
system off if the “maximum collector
temperature” is exceeded. As soon as the
temperature drops 15K below this value, the
system is started up again.
Display
Meaning
Short circuit of temperature sensor for current measuring point
Break to temperature sensor of current measuring point, circulation
error if energy yield estimation is activated