IMAGE FUSING
G031/G032 2-34 SM
The CPU controls the temperature as shown in the following tables to keep the
fusing lamp at the appropriate temperature for each condition.
G031
Condition
Power on
Within 2 minutes
After 2 minutes
Ready to print 170°C 170°C
Standby mode 185°C 175°C
Normal paper 195°C 185°CPrinting
(600 dpi)
Thick paper (> 155 g/m², 41 lb) 195°C 195°C
Normal paper
165°C 160°C * 160°C 155°C *
Printing
(1,200 dpi)
Thick paper (> 155 g/m², 41 lb) 165°C 160°C
*: After 26 seconds at 1,200 dpi using normal paper, the temperature is reduced.
G032
Condition
Power on
Within 2 minutes
After 2 minutes
Ready to print 170°C 170°C
Standby mode 175°C 165°C
Normal paper 185°C 175°CPrinting
(600 dpi)
Thick paper (> 155 g/m², 41 lb) 185°C 185°C
Normal paper
150°C 145°C * 145°C 140°C *
Printing
(1,200 dpi)
Thick paper (> 155 g/m², 41 lb) 150°C 145°C
*: After 15 seconds at 1,200 dpi using normal paper, the temperature is reduced.