12 March 1999 FUSING UNIT
SM 6-5 G031/G032
Replacement
and
Adjustment
6.2.2 HOT ROLLER AND FUSING LAMP REPLACEMENT
1. Remove the fusing unit. (Refer to Fusing Unit Replacement, section 6.2.1.)
2. Remove the fusing cover [A] (2 screws).
3. Remove the fusing exit sensor [B].
4. Remove the bracket [C] and the spring [D]. (G031 has two brackets [C] and two
springs [D], G032 has one of each.)
5. Separate the fusing unit (2 screws [E]).
G031R542.WMF
[B]
[A]
[C]
[D]
[E]