Savin Aficio SP3300DN Manual de servicio Pagina 125

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 138
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 124
Engine Hardware Specifications
SM 6-11 M000/M009
Detailed
Descriptions
Error Description
OPEN HEAT ERROR
When warming up, it has been lower than 90°C over 20
seconds.
LOW HEAT ERROR
Standby - It has been lower than the Standby Reference
Temperature -20°C over 10 seconds.
Printing has been lower than the Printing Reference
Temperature -20°C over 10 seconds.
When Warm-Up End Process, it has been lower than the
Warm-Up Reference Temperature -10°C over 10 seconds.
OVER HEAT ERROR
It has been higher than 220°C over 20 seconds.
It has been higher than 230°C over 3 seconds.
It has been higher than Standby Reference Temperature
+10°C over 180 seconds.
This can be changed in the future.
LSU
The LSU consists of the LD (Laser Diode) and the polygon motor control. When the printing
signal occurs, it turns on the LD and drives the polygon motor. When the detector detects
the beam, Hsync occurs. Error messages are as follows:
Error Description
Polygon Motor Error When the polygon motor speed does not become steady.
LOW HEAT ERROR
The polygon motor speed is steady but Hsync is not
generated.
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA
Vista de pagina 124
1 2 ... 120 121 122 123 124 125 126 127 128 129 130 ... 137 138

Comentarios a estos manuales

Sin comentarios